The camera found a problem in the flue. Here is what comes next
Price a flue repair
Tell us what the report said, what the fireplace burns and whether you plan to change it.
What the camera shows
Picture a gray tunnel lit from below. The clay tiles show as smooth square sections stacked one above another. A crack reads as a black line, sometimes straight across, sometimes a jagged diagonal. A missing joint shows as a gap between two tiles where you can see the brick behind. Heavy creosote looks like black glossy bubbles, and a flue with no liner at all shows rough brick and mortar the whole way up.
Each of those means the same thing in practice: heat and smoke can reach the masonry and, through it, the wood framing of the house. A flue in that condition fails a Level 2, and it is also a flue that drafts poorly, which is why the fireplace may have been smoking into the room.
The usual flue fixes
Relining is the most common answer. A stainless steel liner runs the full height of the chimney inside the old flue, connected at the bottom to the firebox or to the appliance and capped at the top. It is sized to whatever burns below it, which matters for draft and for cleaner burning: a gas insert, a wood stove and an open fireplace each want a different diameter.
Where only a few tiles are cracked and the rest are sound, some flues can be repaired with a coating system applied from inside. Where the chimney has no liner at all, a new liner is the only route to passing. Factory-built fireplaces are different again: their flue pipe is part of a tested system, and failed sections are replaced with matching parts.
- Stainless relining for wood, gas or a new insert
- Coating repair for a small number of cracked tiles
- Replacement pipe sections on factory-built units
- Cap, flashing and cricket work found on the same visit
When a fix doubles as an upgrade
If the flue needs a new liner anyway, it is the cheapest moment to change what burns at the bottom. A sealed gas insert uses its own vent pipes, so the relining and the insert become one job. For owners tired of smoke and no-burn days, that is often the route that makes sense.
After the work we run the camera again so the report shows the repaired flue, not just the old failure.
Fix prices
Our published figures for the repairs that most often follow a flue finding. Liner, crown, damper and chase cover work is priced after we measure.
- Sealed gas heater fitted into the old firebox, vented
- $2,700 to $5,450
- Leak traced to its source and sealed
- $545 to $3,250
- Cricket behind a wide stack
- $435 to $985
- Cricket and fresh flashing together
- $655 to $1,600
- Repeat camera run, before or after
- $380
- Cap over the flue, fitted
- Quoted after we measure
A range covers small and large versions of the same job; the written quote places your chimney in it.
Flue repair questions
Can I keep using the fireplace until the repair is done?
Not if the report graded the flue as unsafe. A cracked or missing liner lets heat reach the framing, and the risk does not show until it is too late.
Is relining always cheaper than rebuilding?
Usually, when the masonry outside is sound. If the chimney itself is failing, a liner alone will not fix it and the quote will say so.
Does a gas insert need a new liner?
Yes. The insert vents through its own pipes up the full height of the chimney. That is part of the insert job, not an extra.
Will the buyer accept a coating repair?
When the coating is done to the maker's system and a new camera run shows the result, most do. We include the after footage in the report.
My chimney has two flues. Does each need its own fix?
Each flue is judged on its own. One may pass while the other needs a liner.
Holding a flue finding from a report?
Send what the report said through the contact page, along with what the fireplace burns now, and we will set a visit to measure and price the fix.
Call (949) 879-2606